Compact hygienic Coriolis flowmeter for direct mass-based filling and dosing, with electropolished 316L measuring tubes, Ra ≤ 0.4 µm internal surface and CIP/SIP capability.
MassFill 7000 is the hygienic configuration of the MassFill Coriolis platform, developed for direct mass-based filling and dosing in food, dairy, pharmaceutical and clean-process production environments.
Its Stainless Steel 316L measuring tubes are electropolished to an internal surface roughness of Ra ≤ 0.4 µm. Combined with CIP/SIP capability and flanged or standardized clamp connections, this construction supports processes involving frequent cleaning, sterilization and product changeover.
The Coriolis measuring principle provides direct mass-flow measurement without requiring electrical conductivity from the liquid. Density, temperature and volume-flow information are also available, supporting multi-product filling and dosing where product properties may vary between recipes or production runs.
Batch Filling and Tri-State Filling are integrated into the instrument platform. The Low–High–Low Tri-State profile provides controlled initial and final filling while allowing greater throughput during the main filling stage.
The compact, displayless transmitter operates from 18–30 V DC and uses an 8-pin M12 connector for power, I/O and communication. Three selectable I/O configurations, pulse output up to 4 kHz and Modbus RTU allow direct integration into filling-machine PLCs and OEM control architectures.
An optional PrismaTech HMI can provide a dedicated operator interface where required. MassFill 7000 is compact-only and does not require a remote transmitter configuration.
| Measuring Principle | Coriolis |
| Measured Variables | Mass Flow, Volume Flow, Density, Temperature |
| Mass Flow Measuring Range | 0 to 350,000 kg/h, depending on nominal size |
| Mass Flow Accuracy – Liquid | ±0.15% of reading standard; ±0.10% of reading optional |
| Mass Flow Accuracy – Gas | ±0.75% of reading |
| Mass Flow Repeatability – Liquid | ±0.075% standard; ±0.05% optional |
| Density Accuracy – Liquid | ±0.5 kg/m³ under reference conditions |
| Density Repeatability – Liquid | ±0.25 kg/m³ |
| Totalizers | 2 independent totalizers with selectable units |
| Pulse Output | Configurable quantity per pulse |
| Maximum Pulse Frequency | 4 kHz |
| Filling Functions | Batch Filling / Tri-State Filling |
| Nominal Size Range | DN8 to DN100 |
| Measuring Tube Material | Stainless Steel 316L |
| Surface Treatment | Electropolished |
| Internal Surface Roughness | Ra ≤ 0.4 µm |
| Process Connection Wetted Parts | Stainless Steel 316L |
| Sensor Housing Material | Stainless Steel 304 |
| Transmitter Housing Material | Stainless Steel 304 standard; Stainless Steel 316 optional |
| Installation Configuration | Compact only |
| Process Connections | Flanged / Clamp |
| Available Flange Standards | ASME B16.5 / EN 1092-1 / JIS B2220 |
| Standard Flange Configuration | ASME B16.5 Class 150 |
| Max. Process Pressure – Flanged | PN100 / ASME Class 600 / JIS 63K |
| Available Clamp Standards | DIN 32676 / ASME BPE |
| Fluid Temperature Range | −50 to +150 °C |
| Ambient Temperature Range | −20 to +60 °C |
| Degree of Protection | IP67 |
| CIP/SIP Capability | Suitable for CIP cleaning and SIP sterilization within specified operating limits |
| Power Supply | 18–30 V DC only |
| Electrical Connection | 8-pin M12 connector |
| Digital Input | 1 × configurable digital input |
| Digital Output | According to selected I/O configuration |
| Switch Output | Galvanically isolated solid-state switch output, normally open |
| Switch Technology | PhotoMOS solid-state switching |
| Pulse Function | Configurable through digital output; maximum frequency 4 kHz |
| Configuration | Available I/O |
|---|---|
| 1 | 1 × Digital Output + 1 × Digital Input + Modbus RTU |
| 2 | 2 × Digital Outputs + 1 × Digital Input + Modbus RTU |
| 3 | 1 × Galvanically Isolated Solid-State Switch Output + 1 × Digital Input + Modbus RTU |
| Digital Communication | Modbus RTU over RS-485 |
| External HMI | Optional PrismaTech HMI via Modbus RTU over RS-485 |
| Calibration | Flow calibration performed under ISO/IEC 17025 accreditation |
| Quality Management | ISO 9001 / ISO 29001 |
| Manufacturing Compliance | GMP requirements |