Explosion-Proof Custody Transfer Coriolis Mass Flowmeter for Petroleum Fluids

Product Specifications

✓ Certified to ATEX standards for safe operation in Hazardous Areas and potentially explosive environments in the oil, gas, and petrochemical industries.

✓ Universal Measurement Principle for all gases and liquids.

✓ Achieves highly accurate measurement of volumetric flow, mass flow, and density.

✓ Enhanced flexibility and compatibility with a wide variety of process fluids.

✓ Equipped with an Explosion-Proof (Flameproof) transmitter featuring 0/4–20 mA analog, digital, and pulse outputs.

✓ Supports industrial communication networks and protocols including: Modbus (RTU & TCP/IP), Profibus, HART, and Ethernet.

✓ Minimizes maintenance requirements and provides high reliability due to the absence of moving parts.

✓ Wide measuring range from 0–800,000 kg/h.

✓ Wide operating temperature range from −40°C to +250°C (with ATEX-compliant temperature classes).

✓ Resistant to vibration and harsh environmental conditions.

✓ Available in sizes ranging from DN8 to DN150.

Description

Coriolis Mass Flow Meter Explosion-Proof is used across a wide range of industrial applications, including the food, pharmaceutical, oil, gas, petrochemical, and even natural sciences sectors.

Coriolis flow meters are capable of measuring most fluids in partial, slurry, and high-viscosity cases, including detergents, vegetable and animal oils, crude oil, plant syrups, alcohols, and even gases.

Simultaneous measurement of mass flow, density, and temperature by Coriolis mass flow meters opens up new possibilities for improving industrial process control, enhancing product quality monitoring, and ensuring greater operational safety.

Sizes of the Coriolis Mass Flow Meter Explosion-Proof

PrismaTech Coriolis mass flow meters are available in various sizes ranging from DN 8 to DN 150. The measuring tubes are made of stainless steel AISI 316L. These flow meters are equipped with an ARM Cortex M7 processor and a 320×240 TFT LCD display.

In the mechanical structure of the Coriolis mass flow meter with a dual U-shaped tube design, there is an electromagnetic actuator positioned at the center of the tubes and two velocity sensors located on either side. When the actuator is properly controlled, the tubes begin to oscillate at their structural resonance frequency.

By measuring the vibration frequency and performing temperature calibration, the density of the fluid passing through the U-shaped tubes can be determined with high accuracy. Meanwhile, as the fluid flows through the tubes, a phase difference develops between the two sensors, and the magnitude of this difference is proportional to the mass flow rate. Therefore, by measuring the phase shift between the magnetic sensors, the mass flow rate can be precisely determined. With both mass flow and density known, the volumetric flow can also be calculated.

0/5 (0 Reviews)

Technical Specifications

Additional information

Product family name

PrismaTech coriolis mass flowmeter series

Product type

PTMAS

Measurement principle

Coriolis

Measurment parameters

Mass flow, Volumetric Flow, Density and Temperature

Accuracy (liquids)

±0.15% (Optional ±0.1) Reading

Accuracy (gases)

±0.75% Reading

Accuracy (density)

±0.001gr/cm3 (Optional ±0.005gr/cm3) Reading

Accuracy (temperature)

±0.5°C

Rangeability

01:20

Repeatability

0.5%

Contact to measured medium

Yes

Measured media

Liquids and Gases

Ambient temperature

-40…+60°C

Nominal diameter / size

DN8…DN150

Process pressure

100 bar

Process temperature

-40… +150°C (Optional -40… +250°C)

Tube material

AISI316L (Optional Hastelloy and etc.)

Sensor body material

AISI304, AISI316L

Sensor protection

IP67

Transmitter protection

IP66

Tube roughness

<1.4µm (Optional <0.4µm)

Connections

ASME (B 16.5) Class 150-600: DN8…DN150 Flange
ISO7005 PN16-100: DN8…DN150 Flange

Analogue outputs

Two units 0/4…20 mA (Flow rate,Temperature, PID controller, etc.)

Digital inputs

One unit (Total reset, Hold, Filling reset, etc.)

Digital outputs

Two units (Puls, Switch, Batch filling, etc.)

Communications

"Modbus RTU (RS485)
Optional (Modbus TCP/IP, Ethernet IP, Profibus DP ,Hart, Wifi)"

Cable connection

Gland M20

Transmitter body material

Painted Aluminium

Display

320×240 TFT color LCD, None

Approvals

ATEX: II 1G Ex ia IIC T6 … T1 Ga for remote sensor
ATEX II 2G Ex db IIC T6 Gb for Integrated

Videos & Clips of Product

Catalogue & Manual Instruction

English Catalogue

Explosion-Proof Custody Transfer Coriolis Mass Flowmeter for Petroleum Fluids

Consultation Form

  1. You can call us by methods of Contact Us page.
  2. You can fill this form and our experts will get in touch with you as soon as possible.

Ordering Form

  1. You can call us by methods of Contact Us page.
  2. You can fill this form and our experts will get in touch with you as soon as possible.

فرم جستجو

اگر صفحه مورد نظر شما، در لیست صفحات پایین نیست. در فرم جستجو کنید.